Pending ID Timer:
This timer times inter-activity ID timer so a proper Pending ID can be sent during activity.
- This timer is programmed in 1Sec increments from 1..9999
- If a timer value of 0 is entered, the controller will never send a rotating ID.
- This timer should normally be set shorter than the initial ID timer (one minute shorter works
well). You may need to make sure that the length of this timer plus the length of the impolite ID
timer is less than 10 minutes to meet requirements for ID timing.
Timer Number Description Defaults
48 Pending ID Timer, Port 1 9 min (540)
49 Pending ID Timer, Port 2 "
50 Pending ID Timer, Port 3 "
51 Pending ID Timer, Port 4 "
Timeout Timer:
This timer limits how long a receiver can be continuously active. If the receiver is active longer
than the length of this timer, its time out message is sent out all transmitters that are connected to it
and it is disabled until it goes inactive. It is reset and the time out clear message is sent when the
timed out receiver goes inactive.
- This timer is programmed in 1 second increments from 1..9999
- If a timer value of 0 is entered, the controller will never time-out.
Timer Number Description Defaults
52 Time Out Timer, Port 1 3 Min. (180)
53 Time Out Timer, Port 2 "
54 Time Out Timer, Port 3 "
55 Time Out Timer, Port 4 "