4.16.2 Frequency Limit Using Upper and Lower Limit
Frequency Values
Group
Code
Name
Setting
Setting Range
Unit
Ad
24
Frequency limit
0
No
01
-
25
Frequency lower
limit value
0.50
0.0maximum
frequency
Hz
26
Frequency upper
limit value
Maximum
frequency
Lower limit
maximum
frequency
Hz
Frequency Limit Using Upper and Lower Limit Frequencies - Setting Details
Code and
Features
Description
Ad.24 Freq Limit
The initial setting is 0 (No). When the setting is changed to 1
(Yes), the frequency can be set only between the lower limit
frequency (Ad.25) and the upper limit frequency (Ad.26). When
the setting is 0 (No), codes Ad.25 and Ad.26 are not visible.
Ad.25 Freq Limit Lo,
Ad.26 Freq Limit Hi
Set an upper limit frequency to all speed unit parameters that are
expressed in Hz or rpm, except for the base frequency (dr.18).
Frequency cannot be set higher than the upper limit frequency.