6.3.6 Inverter Diagnosis State
Check the diagnosis of components or devices for inverter to check if they need to be
replaced.
Group
Code
Name
Setting
Setting Range
Unit
89
FAN
replacement
warning
Bit
0001
Bit
00
-
01
FAN Warning
6.3.7 Operation Mode on Option Card Trip
Option card trips may occur when an option card is used with the inverter. Set the
operation mode for the inverter when a communication error occurs between the
option card and the inverter body, or when the option card is detached during
operation.
Group
Code
Name
Setting
Setting Range
Unit
Pr
80
Motion selection at
option trip
0
None
03
-
1
Free-Run
2
Dec
Operation Mode on Option Trip Setting Details
Code and
Features
Description
Pr.80 Opt Trip
Mode
Configuration
Function
0
None
No operation.
1
Free-Run
The inverter output is blocked and fault trip
information is shown on the keypad.
2
Dec
The motor decelerates to the value set at Pr.07
(Trip Dec Time).

Table of Contents

Other manuals for LSIS G100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS G100 and is the answer not in the manual?

LSIS G100 Specifications

General IconGeneral
BrandLSIS
ModelG100
CategoryInverter Drive
LanguageEnglish

Related product manuals