4 Learning Basic Features
This chapter describes the basic features of the G100 inverter. Check the reference
page in the table to see the detailed description for each of the basic features.
Basic Tasks
Use Example
Ref.
Frequency reference
source configuration for
the keypad
Configures the inverter to allow you to setup or
modify frequency reference using the Keypad.
p.60
Frequency reference
source configuration for
the terminal block (input
voltage)
Configures the inverter to allow input voltages at
the terminal block (V1) and to setup or modify a
frequency reference.
p.61
Frequency reference
source configuration for
the terminal block (input
current)
Configures the inverter to allow input currents at
the terminal block (I2) and to setup or modify a
frequency reference.
p.67
Frequency reference
source configuration for
RS-485 communication
Configures the inverter to set the frequency to the
upper level controllers, such as PLCs or PCs, via
the communications terminal (S+/S-) of the
terminal block or the RJ45 connector.
p.70
Frequency Hold by
Analog Input
Enables the user to hold a frequency using analog
inputs at terminals.
p.70
Multi-step frequency
configuration
Configures multi-step frequency operations by
receiving an input at the terminals defined for each
step frequency.
p.71
The Keypad as a
Command Input Device
Configures the inverter to start the operation with
the [RUN] key on the keypad and stop with the
[STOP/RESET] keys.
p.73
Command source
configuration for
terminal block inputs
Configures the inverter to accept inputs at the
FX/RX terminals.
p.73
RS-485 Communication
as a Command Input
Device
Configures the inverter to allow communication
signals from upper level controllers, such as PLCs
or PCs, and to set up an operation command
using S+ and S- terminals or the RJ45 connector.
p.75
Forward or Reverse
Run Prevention
Configures the inverter to limit a motor’s rotation
direction.
p.75
start at power-on
Configures to accelerate instantly if the operation
command is on when inverter power is supplied.
p.76
Automatic restart after
reset of a fault trip
condition
Configures the inverter to start operating if the
operation command is on after the inverter is reset
following a fault trip.
p.77

Table of Contents

Other manuals for LSIS G100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS G100 and is the answer not in the manual?

LSIS G100 Specifications

General IconGeneral
BrandLSIS
ModelG100
CategoryInverter Drive
LanguageEnglish

Related product manuals