EasyManua.ls Logo

LSIS G100 - Page 133

LSIS G100
343 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Group
Code
Name
Setting
Setting Range
Unit
23
Operation time during
deceleration
0.0
0.060.0
sec
Note
Dwell operation does not work when:
Dwell operation time is set to 0 sec or dwell frequency is set to 0 Hz.
Re-acceleration is attempted from stop or during deceleration, as only the first
acceleration dwell operation command is valid.
[Acceleration dwell operation]
Although deceleration dwell operation is carried out whenever stop commands are
entered and the deceleration dwell frequency is passed through, it does not work
during a deceleration by simple frequency change (which is not a deceleration due to a
stop operation), or during external brake control applications.
[Deceleration dwell operation]

Table of Contents

Other manuals for LSIS G100

Related product manuals