Group
Code
Name
Setting
Setting Range
Unit
23
Operation time during
deceleration
0.0
0.060.0
sec
Note
Dwell operation does not work when:
Dwell operation time is set to 0 sec or dwell frequency is set to 0 Hz.
Re-acceleration is attempted from stop or during deceleration, as only the first
acceleration dwell operation command is valid.
[Acceleration dwell operation]
Although deceleration dwell operation is carried out whenever stop commands are
entered and the deceleration dwell frequency is passed through, it does not work
during a deceleration by simple frequency change (which is not a deceleration due to a
stop operation), or during external brake control applications.
[Deceleration dwell operation]