EasyManuals Logo

LSIS G100 User Manual

LSIS G100
343 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #242 background imageLoading...
Page #242 background image
Comm.
Address
Parameter
Scale
Unit
R/W
Assigned Content by Bit
0h0009
Output current
0.1
A
R
-
0h000A
Output frequency
0.01
Hz
R
-
0h000B
Output voltage
1
V
R
-
0h000C
DC link voltage
1
V
R
-
0h000D
Output power
0.1
kW
R
-
0h000E
Operation status
-
-
-
B15
Reserved
B14
1: Frequency command
source by
communication (built-in,
option)
B13
1: Operation command
source by
communication (built-in,
option)
B12
Reverse operation
command
B11
Forward operation
command
B10
Brake release signal
B9
Jog mode
B8
Drive stopped.
B7
DC Braking
B6
Speed reached
B5
Decelerating
B4
Accelerating
B3
Fault Trip - operates
according to OU.30
setting
B2
Operating in reverse
direction
B1
Operating in forward
direction
B0
Stopped
0h000F
Fault trip information
-
-
R
B15
Reserved
B14
Reserved
B13
Reserved
B12
Reserved
B11
Reserved
B10
H/W-Diag
B9
Reserved
B8
Reserved
B7
Reserved
B6
Reserved
B5
Reserved
B4
Reserved

Table of Contents

Other manuals for LSIS G100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS G100 and is the answer not in the manual?

LSIS G100 Specifications

General IconGeneral
BrandLSIS
ModelG100
CategoryInverter Drive
LanguageEnglish

Related product manuals