MAN B&W 6.04
Page 1 of 12
MAN Diesel
198 71 49-5.6MAN B&W G80ME-C9.2.68-TII, S70MC-C8.2-TII,
S70ME-C8.2/-GI-TII, S65ME-C/ME-GI8.2-TII, S/L60MC-C8.2-TII,
S60ME-C8.2/-GI-TII, S60ME-B8-TII, L60ME-C8.2-TII,
G50ME-B9.3-TII, S50MC-C8.2-TII, S50/ME-C8.2/-GI-TII,
S50ME-B8/9-TII, S46MC-C8-TII, S46ME-B8-TII, G45ME-B9.3-TII,
G40ME-B9.3-TII, S40MC-C9.2-TII, S40ME-B9-TII, S35ME-B9-TII,
S35MC-C9.2-TII, S30ME-B9.3-TII
Auxiliary Machinery Capacities
The dimensioning of heat exchangers (coolers)
and pumps for derated engines can be calculated
on the basis of the heat dissipation values found
by using the following description and diagrams.
Those for the nominal MCR (L
1
), may also be used
if wanted.
The nomenclature of the basic engine ratings and
coolers, etc. used in this section is shown in Fig.
6.01.01 and 6.01.02.
Cooler heat dissipations
For the specified MCR (M) the following three dia-
grams in Figs. 6.04.01, 6.04.02 and 6.04.03 show
reduction factors for the corresponding heat dis-
sipations for the coolers, relative to the values
stated in the ‘List of Capacities’ valid for nominal
MCR (L
1
).
The percentage power (P
M%
) and speed (n
M%
) of L
1
ie: P
M%
= P
M
/P
L1
x 100%
n
M%
= n
M
/n
L1
x 100%
for specified MCR (M) of the derated engine is
used as input in the abovementioned diagrams,
giving the % heat dissipation figures relative to
those in the ‘List of Capacities.
Q
air%
= 100 x (P
M
/P
L1
)
1.68
x (n
M
/n
L1
)
– 0.83
= 1
178 63 63-8.0
Fig. 6.04.01: Scavenge air cooler, heat dissipation Q
air%
in
point M, in % of the L
1
value Q
air, L1
Q
jw%
= e
(– 0.0811 x ln (n
M%
)
+ 0.8072 x ln (P
M%
) + 1.2614)
Fig. 6.04.02: Jacket water cooler, heat dissipation Q
jw%
in point M, in % of the L
1
value Q
jw, L1
178 63 62-6.1
Q
lub%
= 67.3009 x ln (n
M%
) + 7.6304 x ln (P
M%
)
 245.0714
Fig. 6.04.03: Lubricating oil cooler, heat dissipation
Q
lub%
in point M, in % of the L
1
value Q
lub, L1
178 63 65-1.1
Specified MCR power, % of L
1
P
M%
110%
100%
90%
80%
70%
60%
80% 85% 90% 95% 105%100% 110%
n
M%
Specified MCR engine speed, % of L
1
L
2
L
4
L
1
L
3
82%
78%
86%
90%
94%
98%
100%
Q
jw%
M
Specified MCR power, % of L
1
P
M%
110%
100%
90%
80%
70%
60%
80% 85% 90% 95% 105%100% 110%
n
M%
Specified MCR engine speed, % of L
1
L
2
L
4
L
1
L
3
88%
90%
92%
94%
96%
98%
100%
Q
lub%
M
Specified MCR power, % of L
1
P
M%
110%
100%
90%
80%
70%
60%
80% 85% 90% 95% 105%100% 110%
n
M%
Specified MCR engine speed, % of L
1
L
2
L
4
L
1
L
3
Q
air%
100%
90%
80%
70%
M
65%

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Man B&W S50ME-B9.3-TII and is the answer not in the manual?

Man B&W S50ME-B9.3-TII Specifications

General IconGeneral
BrandMan
ModelB&W S50ME-B9.3-TII
CategoryEngine
LanguageEnglish

Related product manuals