EasyManua.ls Logo

Man B&W S50ME-B9.3-TII - Pressure losses and coefficients of resistance in exhaust pipes

Man B&W S50ME-B9.3-TII
337 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAN B&W 15.05
Page 3 of 3
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 40 949.3
90
60
30
90
45
D
R
D
R
D
D
R
D
Changeover valves
Changeover valve
of type with con-
stant cross section
ζa = 0.6 to 1.2
ζb = 1.0 to 1.5
ζc = 1.5 to 2.0
Changeover valve
of type with volume
ζa = ζb = about 2.0
M: Measuring points
Fig. 15.05.01: Pressure losses and coefficients of resistance in exhaust pipes
178 32 091.0 178 06 853.0
R = D ζ = 0.28
R = 1.5D ζ = 0.20
R = 2D ζ = 0.17
R = D ζ = 0.16
R = 1.5D ζ = 0.12
R = 2D ζ = 0.11
ζ = 0.05
R = D ζ = 0.45
R = 1.5D ζ = 0.35
R = 2D ζ = 0.30
ζ = 0.14
Outlet from ζ = 1.00
top of exhaust
gas uptake
Inlet (from
turbocharger) ζ = – 1.00
Pressure losses and coefcients of resistance in exhaust pipes
Spark
arrester
Silencer
Exhaust
gas boiler
M
M
M
M
M
T/C
M
tc
M
tc
p
1
p
2
p
tc
p
3
a
a
b
c
a
b
90
60
120

Table of Contents