Auxiliary equipment system
The input signals for ‘Auxiliary system ready’ are
given partly based on the status for:
• fuel oil system
• lube oil system
• cooling water systems
and partly from the ECS
• turning gear disengaged
• main starting valve ‘open’
• control air valve for sealing air ‘open’
• control air valve for air spring ‘open’
• auxiliary blowers running
• hydraulic power supply ready
Instrumentation
Chapter 18 in the Project Guide for the specific
engine type includes lists of instrumentation for:
The class requirements and MAN Diesel & Turbo’s
requirements for alarms, slow down and shut
down for Unattended Machinery Spaces.