MAN B&W 16.01
Page 6 of 8
MAN Diesel
MAN B&W ME-B engines 198 51 84-2.3
Auxiliary equipment system
The input signals for ‘Auxiliary system ready’ are
given partly based on the status for:
fuel oil system
lube oil system
cooling water systems
and partly from the ECS
turning gear disengaged
main starting valve ‘open’
control air valve for sealing air ‘open’
control air valve for air spring ‘open’
auxiliary blowers running
hydraulic power supply ready
Instrumentation
Chapter 18 in the Project Guide for the specific
engine type includes lists of instrumentation for:
The class requirements and MAN Diesel & Turbo’s
requirements for alarms, slow down and shut
down for Unattended Machinery Spaces.