Maintenance work on the carrier
7.17 Air-conditioning system
7 - 114 3 302 577 en Maintenance manual
GMK7450
16.08.2018
7.17.3 Cleaning the condenser fins
Switch the air-conditioning system off;
à Operating manual.
Clean the fins of the condenser (2) and the
fan (1) with compressed air.
7.17.4 Checking the entire air-conditioning system
H
This inspection may only be performed by Manitowoc Crane Care or an
authorised GROVE dealer or an authorised specialist workshop!
Have the entire air-conditioning system checked for leaks and proper
functioning.
The inspection of the air-conditioning system particularly includes the
inspection of
The refrigerant
collector, in accordance with the pressure container
regulations (test group
II) and
The refrigerant compressor.
Only allow the system to be topped up with suitable refrigerant.
M 12
S
Risk of damage to the condenser!
Do not use a high pressure cleaner or steam jet cleaner. The hard jet can
damage the fins and the fan. Use
only compressed air for cleaning.
M 12
G
Risk of burns due to escaping refrigerant!
Wear suitable safety glasses and gloves when checking the hoses and con-
nections.
This will prevent injury from suddenly escaping refrigerant. Seek medical
attention
if the skin or eyes come into contact with the refrigerant.