Maintenance work on the superstructure
8.11 Main boom
16.08.2018
Maintenance manual 3 302 577 en 8 - 95
GMK7450
8.11.5 Checking the locking system
Have the main boom locking system checked regularly by
Manitowoc Crane Care or an authorised GROVE dealer.
M 12
G
Risk of accidents if maintenance work is not carried out!
Have the maintenance work on the main boom locking system performed
regular
ly by
Manitowoc Crane Care or an authorised GROVE dealer.
This prevents the complete unlocking of a telescopic section in Emergency
operation/Emergency program
mode, which could cause serious accidents
and damage to the truck crane.