Maintenance work on the superstructure
8.5 Exhaust system with exhaust emission control
16.08.2018
Maintenance manual 3 302 577 en 8 - 37
GMK7450
Refuelling • Find out about filling up in the operating manual and note the warnings;
à Operating manual.
• Fill the AdBlue tank via the filler neck (1) and
close it using the cap.
• Secure the cap with the securing plug (2).
• Check the filling level on the display in the
crane cab;
à P. 8 - 36.
8.5.3 Check the exhaust system for external damage
Spare parts and
tools
Prerequisites – The engine must not be running and must be secured against unauthor-
ised use;
à P. 2 - 3.
– The engine and the exhaust system must be cool.
s
G
Danger of scalding due to ammonia vapours!
Ammonia vapour can escape if the AdBlue tank is opened when the outside
temperature is high. Ammonia va
pours can irritate mucous membranes,
skin and eyes.
Ensure that there is adequate fresh air supply and do not breathe in the
escaping ammonia vapours.
Designation Quantity GROVE part no.
Entire exhaust system
– DOC catalytic converter + DPF particle
filter
– A
dBlue mixing tube
– SCR catalytic converter
1
1
1
1
04168803
04168812
04168809
04168808