EasyManua.ls Logo

Manitowoc GROVE GMK7450 - Changing the Pollen Filter

Manitowoc GROVE GMK7450
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance work on the carrier
7.17 Air-conditioning system
7 - 116 3 302 577 en Maintenance manual
GMK7450
16.08.2018
7.17.5 Changing the pollen filter
Reducing the
interval
Under difficult operating conditions – at extremely sandy or dusty loca-
tions – you must change the pollen filter earlier than usual.
Spare parts and
tools
Prerequisites The engine must not be running and must be secured against unauthor-
ised use;
à P. 2 - 3.
Changing
Air-conditioning system
Remove the frame (1).
Remove the filter (2) from the housing and
clean the housing with a cloth.
Insert a new filter.
Fasten the frame (1).
M 12
Designation Quantity GROVE part no.
Pollen filter for roof air-conditioning system
(184-192-0016 24V Aurora; cpl.)
1 03268376 cpl.
Pollen filter for heating system 1 02212145

Table of Contents

Related product manuals