Maintenance work on the carrier
7.17 Air-conditioning system
7 - 116 3 302 577 en Maintenance manual
GMK7450
16.08.2018
7.17.5 Changing the pollen filter
Reducing the
interval
• Under difficult operating conditions – at extremely sandy or dusty loca-
tions – you must change the pollen filter earlier than usual.
Spare parts and
tools
Prerequisites – The engine must not be running and must be secured against unauthor-
ised use;
à P. 2 - 3.
Changing
Air-conditioning system
• Remove the frame (1).
• Remove the filter (2) from the housing and
clean the housing with a cloth.
• Insert a new filter.
• Fasten the frame (1).
M 12
Designation Quantity GROVE part no.
Pollen filter for roof air-conditioning system
(184-192-0016 24V Aurora; cpl.)
1 03268376 cpl.
Pollen filter for heating system 1 02212145