EasyManuals Logo
Home>Manitowoc>Construction Equipment>GROVE GMK7450

Manitowoc GROVE GMK7450 User Manual

Manitowoc GROVE GMK7450
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #324 background imageLoading...
Page #324 background image
Maintenance work on the superstructure
8.17 Air-conditioning system
8 - 122 3 302 577 en Maintenance manual
GMK7450
16.08.2018
8.17.3 Cleaning the condenser fins
•
Switch the air-conditioning system off.
• Clean the condenser fins (2) and the fans (1)
with compressed air.
8.17.4 Checking the entire air-conditioning system
H
This inspection may only be performed by Manitowoc Crane Care or an
authorised GROVE dealer or an authorised specialist workshop!
• Have the entire air-conditioning system checked for leaks and proper
functioning.
The inspection of the air-conditioning system particularly includes the
inspection of
– t
he refrigerant collector, in accordance with the pressure container reg-
ulations (test group II) and
– the refrigerant compressor.
Only allow the system to be topped up with suitable refrigerant.
M 12
S
Risk of damage to the condenser!
Do not use a high pressure cleaner or steam jet cleaner. The powerful jet
may damage the fins.
Use only compressed air for cleaning.
M 12
G
Risk of burns due to escaping refrigerant!
Wear suitable safety glasses and gloves when checking the hoses and con-
nections.
This will prevent injury from suddenly escaping refrigerant. Seek medical
attention
if the skin or eyes come into contact with the refrigerant.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK7450 and is the answer not in the manual?

Manitowoc GROVE GMK7450 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK7450
CategoryConstruction Equipment
LanguageEnglish

Related product manuals