Maintenance work on the superstructure
8.9 Pump transfer case
8 - 66 3 302 577 en Maintenance manual
GMK7450
16.08.2018
8.9.3 Changing the oil
Oil, spare parts
and tools
– Receptacle, approx. 5 l (1.5 gal);
à P. 2 - 4.
Prerequisites – The gear oil is at operating temperature.
– The truck crane must be level.
– The engine must not be running and must be secured against unauthor-
ised use;
à P. 2 - 3.
Changing the oil
M 12
Gear oil
in litres (gal)
Specifications
Classification
GROVE part no.
3.8 (1.0) Aral Degol BG 220
MIL-L 2105 C
SAE 90
00554217
Designation Quan
tity GROVE part no.
Gasket A21 x 26 x 2 2 03043651
G
Risk of scalding from warm gear oil!
When coming into contact with gear oil that has been warmed up through
operation, you could get sca
lded.
Only let the gear oil escape at operating temperature if it has been checked.
O
Risk of environmental damage due to leaking consumables!
Always let consumables drain into suitable receptacles. Wipe up any con-
sumables that escape.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK7450 and is the answer not in the manual?

Manitowoc GROVE GMK7450 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK7450
CategoryConstruction Equipment
LanguageEnglish

Related product manuals