EasyManua.ls Logo

Manitowoc GROVE GMK7450 - Final Drives - Checking the Oil Level

Manitowoc GROVE GMK7450
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance work on the carrier
7.8 Axle lines
16.08.2018
Maintenance manual 3 302 577 en 7 - 59
GMK7450
7.8.4 Final drives – Checking the oil level
Spare parts and
tools
1)
Additional equipment (2nd axle line driven)
Prerequisites The truck crane must be raised on outriggers and must be level.
The engine must not be running and must be secured against unauthor-
ised use;
à P. 2 - 3.
The parking brake must be released.
Checking the oil
level
Check the oil level at all other final drives in
the same way.
Turn the wheel until the marking (2) is hori-
zontal and is on the right, next to the centre
of the axle.
Remove the drain plug (1).
Check that the oil level is at the mark (2).
Fit a new gasket and tighten the screw.
If the oil level is too low
Top up with oil; à P. 7 - 61.
M 1
For drive Designation Quan-
tity
GROVE part no.
14 x 6 x 14 Gasket 24 x 29 Cu DIN 7603 6 00117145
14 x 8 x 14
1)
Gasket 24 x 29 Cu DIN 7603 8 00117145