EasyManua.ls Logo

Manitowoc GROVE GMK7450 - Checking the Coolant Level

Manitowoc GROVE GMK7450
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance work on the carrier
7.3 Engine
16.08.2018
Maintenance manual 3 302 577 en 7 - 15
GMK7450
7.3.4 Checking the coolant level
You must top up the coolant if the lamp lights up.
Topping up
coolant
Loosen (do not open) the cap (1) to reduce
the pressure if the coolant is at operating
temperature.
Open the cap (1).
The coolant level must be at the lower mark-
ing in the filler neck.
If the coolant level is too low
Top up the coolant.
Composition of the coolant;
à Engine man-
ufacturer’s documentation
.
Close the cap (1).
D
G
There is a risk of scalding when the cooling circuit is hot!
The hot cooling circuit is under pressure. When you open the expansion
tank, you could be scal
ded by escaping vapour/coolant.
Wear suitable protective gloves and cover the cap on the expansion tank
with a rag before op
ening it.
Turn the cap slowly to the first detent in order to allow the pressure to be
released
.
S
Risk of damage to engine due to lack of coolant!
If the coolant has to be topped up frequently, the cooling system may be
leaking. Have the coo
ling system checked by
Manitowoc Crane Care or an
authorised GROVE dealer or your repair crew.