Maintenance work on the superstructure
8.3 Engine
8 - 24 3 302 577 en Maintenance manual
GMK7450
16.08.2018
• Have the radiator units (1) and (2) opened up by the repair specialists, so
that the radiator fins are accessible.
• Have the radiator fins cleaned on both sides, using suitable cleaning
agents.
• Have the fan wheels (5) cleaned.
• Have the grille (3) and the plates (4) cleaned.
• Have the hoses and connections checked for damage and leaks.
• Have any damaged parts replaced.
After checking/
cleaning
• Remove all tools and cleaning equipment.
• Check that all the grilles (3) and plates (4) are secure.
• Start the engine and from a safe distance monitor the free running of the
fan impellers (5).
• Check the respective temperature displays in the driver's cab;
à Operating manual.
• Switch the engine off.
• Check the radiator and connections for leaks.