Maintenance work on the superstructure
8.3 Engine
8 - 24 3 302 577 en Maintenance manual
GMK7450
16.08.2018
Have the radiator units (1) and (2) opened up by the repair specialists, so
that the radiator fins are accessible.
Have the radiator fins cleaned on both sides, using suitable cleaning
agents.
Have the fan wheels (5) cleaned.
Have the grille (3) and the plates (4) cleaned.
Have the hoses and connections checked for damage and leaks.
Have any damaged parts replaced.
After checking/
cleaning
Remove all tools and cleaning equipment.
Check that all the grilles (3) and plates (4) are secure.
Start the engine and from a safe distance monitor the free running of the
fan impellers (5).
Check the respective temperature displays in the driver's cab;
à Operating manual.
Switch the engine off.
Check the radiator and connections for leaks.