Maintenance work on the superstructure
8.4 Fuel system
8 - 30 3 302 577 en Maintenance manual
GMK7450
16.08.2018
Remove the electrical connecting cable (3)
from the water sensor (WIF = Water in Fuel).
Remove the filter (1).
Screw on a new filter (1) and tighten it.
Close the valve (2) manually.
Attach the electrical connecting cable (3) to
the water sensor (WIF = Water in Fuel).
Open the valve – lever (3) parallel to the line.
Actuate the pump (2) until the fluid flowing
out of the screw plug (1) no longer contains
any bubbles.
Close the drain plug (1).
Start the engine and check for leaks.
Remove the receptacle.
H
If you have used a clean receptacle, you can refill the fuel tank with the con-
sumable using a filter.
Otherwise dispose of the consumable properly.