Maintenance overview
5.2 Maintenance plans
16.08.2018
Maintenance manual 3 302 577 en 5 - 9
GMK7450
M 1
Maintenance work on the SUPERSTRUCTURE:
Monthly/after approx. 100 operating hours
Engine
–Notes;
à Engine manufacturer’s documentation à P. 8 - 13
Exhaust system with exhaust emission control
– Check the exhaust system for external damage
à P. 8 - 37
Pump transfer case
– Check the oil level
à P. 8 - 65
Main boom
– Grease the piston rod of the derricking cylinder
à P. 8 - 85
Electrical system
– Checking the batteries
à P. 8 - 118
Air-conditioning system
– Checking the air-conditioning system
à P. 8 - 121
Other maintenance work
– Checking the functioning of the auxiliary heater
à P. 8 - 126

Table of Contents