EasyManua.ls Logo

Microplex SOLID F90 HD - _______________________________________________________________________________________________

Microplex SOLID F90 HD
157 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation 15
_______________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX Operator’s Manual SOLID F90 HD Edition 1.0
!
- Avoid locating the printer close to an air current ( e.g. ventilators).
- The printer should not be exposed to direct sunlight.
- Do not touch the drum surface because the material is easy to
damage.
- Do not expose the printer to abrupt temperature changes.
- In order to run the printer reliably, please maintain the following
environmental conditions:
Temperature: +15°C to +30°C (59°F to 86°F) operating
-10°C to +35°C (14°F to 95°F) non-operating
Relative humidity: 30% to 80% operating
10% to 80% non-operating
Power standards:
- Please connect the power plug to
230 V AC, 50 Hz (Europe, United Kingdom e.g.).
- The max. effective power input is appr. 5.5 kVA.
- The voltage support must not be impaired by interference.
- The printer is provided with a flexible 3x2.5 mm² connection cable
including a CEE plug 3x32. The corresponding CEE socket has to
be provided with a 25A fuse.
- If using an equivalent fixed connection ensure the grounding is
effected.
- Use the printer only within the allowable fluctuation range +10%
of the power voltage.
Conditional connection for the SOLID F90 HD:
The maximum permissible system impedance Z
max
is appr. 0.02 Ohm.
The user of this device has to determine in consultation with the supply
authority, if necessary, that the equipment is connected only to a
supply of that impedance or less!
!
To avoid damage, the devices must be switched off (i.e. cut off
from the power supply) before the user begins connecting the
interface line.

Table of Contents

Related product manuals