60 Panel Functions
_______________________________________________________________________________________________
________________________________________________________________________________________________
MICROPLEX Operator’s Manual SOLID F90 HD Edition 1.0
5.13. Data Interface Configuration
This function is used to set the interface parameters.
ON LINE
SAVE
SAVE
SAVE
SAVE
MENU
SAVE
ON LINE
Panel display
[SOLID F90
HD ]
[Menu Level 1 ]
( ( (
[Configuration ]
[Interface ]
[SIA Timeout ]
[Digit3 0
30 ]
( ( (
[Digit2 04
0 ]
[Save as Setup? ]
Notes
Turn the printer OFF LINE with this key.
Press one of the ARROW keys until
[Configurat
ion ] is displayed.
The currently set value for he timeout is
displayed (here: 30 seconds).
Pressing one of the ARROW keys
changes the value of the current
posit
ion (Digit 3 = left position, in this
example: 0). Pressing the SAVE key
moves you to the next digit (the MENU
key moves you back, if need be).
The timeout (the waiting period for SIA
to switch to the next interface) is
increased to 40 seconds.
In addition this new value can be
saved as setup value (
using the SAVE
key), before the printer is turned ON
LINE again.
Note:
The printer uses SIA (Simultaneous Interface Administration) to check,
which interface is currently used for the transfer of print data.

Table of Contents