EasyManua.ls Logo

MIMAKI UCJV300 Series - Error Messages - Pressure and NCU Issues

MIMAKI UCJV300 Series
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 Troubleshooting
178
Error
number
Message Cause Corrective action
61E NEGATIVE P. OVER
The required negative
pressure cannot be
maintained. (On the negative
side)
621 Excess Negative
Pressure
The required positive
pressure cannot be
maintained. (On the positive
side)
627 INK BOTTLE SET
The ink IC chip could not be
read for a certain period of
time.
1. Check to confirm that the IC chip was
inserted correctly.
2. Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 34)
650 NCU CONNECT
A problem was detected with
the NCU connection.
Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 34)
651 Replace NCU
A problem was detected with
the nozzle clogging
assessment.
The NCU must be replaced. <販売店、
お近くの弊社営業所、またはコールセ
ンターにお問い合わせください。(先
頭大文字)/>
652 NCU NZK CHK (HW)
A problem was detected with
the nozzle clogging
assessment.
Clean the NCU. "NCU
Cleaning"(P. 135)
653 NCU NZK CHK (Mark)
654 NCU CENTER POS
Printing position adjustment
failed.
655 NCU FLUSH POS
656 NCU SN ADJST
Sensor sensitivity adjustment
failed.
657 Replace NCU Ink Pad
The NCU ink absorber is full. The NCU ink absorber must be
replaced. <販売店、お近くの弊社営業
所、またはコールセンターにお問い合
わせください。(先頭大文字)/>
658 NCU SENSOR LV
LOW
The sensor’s sensitivity is
impaired.
Clean the NCU. "NCU
Cleaning"(P. 135)
Replace the NCU if the error does not
clear. <販売店、お近くの弊社営業所、
またはコールセンターにお問い合わせ
ください。(先頭大文字)/>
65b NCU Sens Adj Err H
Sensor sensitivity adjustment
failed.
65c NCU Sens Adj Err L
715 InkHeater Thr
A problem was detected with
the ink heater thermistor.
Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 34)
716 InkHeater Tmp
717 InkHeater Brk
71a UV-DRV Fuse
A UV-DRV PCB fuse blew. Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 34)
901 INVALID OPERATE
The function is disabled due
to an error.
Check the error details.
902 Data Remain
Print (RIP) data was
received.
Switch to REMOTE mode and start
printing or clear the data and abort
printing.
90d No Head Select
A problem was detected with
the print head.
Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 34)
90f Print Area Short
The media is too small for the
print.
Replace with wider or longer media.

Table of Contents

Other manuals for MIMAKI UCJV300 Series

Related product manuals