EasyManuals Logo

Mindray DC-N3S User Manual

Mindray DC-N3S
277 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #216 background imageLoading...
Page #216 background image
13-14 Probes and Biopsy
6. During biopsy procedures, the needle may deviate from
the desired course due to the tissue characteristics or
the type of needle. In particular, needles of small
diameters may deviate to a greater degree.
7. Disinfect the probe and sterilize needle-guided bracket
before and after each ultrasound-guided biopsy
procedure is performed. Fail to do so may cause the
probe and the needle-guided bracket become sources
of infection.
8. Before clean and sterilize needle-guided bracket please
remove the needle-guided bracket from the probe
referring to chapter 12.
9.
The needle mark displayed on the ultrasound image
does not indicate the actual position of the biopsy
needle. Therefore, it should only be used as a
reference. Always monitor the relative positions of the
biopsy needle during the procedures.
10. Adjust the needle mark before the biopsy procedure is
performed.
11. When performing biopsy procedures, use only sterile
ultrasound gel that is certified to be safe. And manage
the ultrasound gel properly to ensure that it does not
become a source of infection.
12. When performing the operation concerning biopsy,
wear sterile gloves.
13. Image of the biopsy target and the actual position of the
biopsy needle:
Diagnostic ultrasound systems produce tomographic
plane images with information of a certain thickness in
the thickness direction of the probe. (That is to say, the
information shown in the images consist all the
information scanned in the thickness direction of the
probe.) So, even though the biopsy needle appears to
have penetrated the target object in the image, it may
not actually have done so. When the target for biopsy is
small, dispersion of the ultrasound beam may lead to
image deviate from the actual position. Pay attention to
this.
If the target object and the biopsy needle appear in the
image as shown in the figures below (For reference
only):
The biopsy needle appears to reach the target object in
the image
Target
Biopsy

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray DC-N3S and is the answer not in the manual?

Mindray DC-N3S Specifications

General IconGeneral
BrandMindray
ModelDC-N3S
CategoryMedical Equipment
LanguageEnglish

Related product manuals