PRO-2000 Series
2
The User Interface
Mounted on the enclosure door, the LCD Display provides the user interface for the PRO-2000. The LCD Display
comprises an LCD card, a display/control escutcheon with configurable LEDs and push buttons, control key switch,
and a buzzer.
The built-in buzzer draws attention to the panel on occurrence of any detected event. The buzzer sounds
intermittently at two different rates: fast for alarms and slow for all other conditions.
The display/control escutcheon interfaces between the operator and the panel. There are 4 sections:
•The Display section provides selectable display lists of the events you want to access. By selecting a Mode,
Alarm, Supervisory, Trouble, Status, Service or Isolate, the appropriate list appears in the LCD.
•The System section provides selections for system maintenance. For example, enable/disable printing, print
the event log, place/remove devices into/from service or isolate mode.
•The User Defined section contains 12 configurable push buttons and 24 status LEDs-one red and one yellow
for each push button.
•The User Control section displays events and provides acknowledge and reset features.
Membrane push button controls acknowledge and silence alarms, reset the detection circuits, and test the panel
display. These controls also enable authorized service personnel to perform service functions. Using the System
keypad, the operator can select different maintenance functions such as the event log, backlighting intensity, and
other maintenance related features.
The LCD Display features a 2 line by 40 character Liquid Crystal Display (LCD) indicating the status of the panel
and all connected input and OUTPUT devices. When an off-normal condition occurs, the first line displays event
occurrence and time, the second line provides a plain language description of the off-normal condition. The text
description for the zone or device is user-defined.
ALARM
VWXSTU YZ
EXIT HELP
8
0
CONTINUE
#
MENU
7
ENTER
*
9
DEF
MNO
5
2
JKL
4
ABC
1
PQR
6
GHI
3
SYSTEM
SUPERVISORY
ENABLED
CONTROLS
RESET
SERVICESTATUS ISOLATE
POWER ON
FAILED
PA NE L
ACKNOWLEDGE
NEXT
LAST
PREV
FIRST
TEST
LAMP
MORE
VISORY
SUPER-
ALARM TROUBLE
DISPLAY
USER DEFINED SECTION
LCD DISPLAY - USER DEFINED MESSAGES
SYSTEM KEY PAD
CONTROL KEY SWITCH
USER CONTROL SECTION
DYSPLAY KEY PADBUZZER
Figure 1: LCD Display

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mircom PRO-2000 Series and is the answer not in the manual?

Mircom PRO-2000 Series Specifications

General IconGeneral
BrandMircom
ModelPRO-2000 Series
CategoryControl Systems
LanguageEnglish

Related product manuals