28 SPECIFICATIONS
28.3 Output Specifications
357
28
High-speed pulse input/output module
The assignment is determined according to the output mode specified in GX Works3.
*1 The number in is the head output number for each high-speed pulse input/output module.
The high-speed pulse input/output modules are ordered as the first module, second module, next modules from nearest to the CPU
module.
Application Output number
*1
First module Second module Third module Fourth module
Axis 5 Axis 6 Axis 7 Axis 8 Axis 9 Axis 10 Axis 11 Axis 12
Pulse output
destination
PULSE/CW Y Y+1 Y Y+1 Y Y+1 Y Y+1
Rotation direction
signal
SIGN/CCW Y+4 Y+5 Y+4 Y+5 Y+4 Y+5 Y+4 Y+5
Clear signal Y+2 Y+3 Y+2 Y+3 Y+2 Y+3 Y+2 Y+3