33 PROGRAMMING
33.2 Cautions for Program Creation
557
33
Output
The following functions occupy outputs of the high-speed input/output function. The following functions cannot be combined
with other high-speed input/output functions.
*1 When positioning is not used, the output devices (Y) for which the positioning setting is enabled with parameters can be used as PWM
outputs or general-purpose devices having no parameter.
Precautions
Do not specify an output device (Y) used by the high-speed input/output function as the output destination of the high-speed
comparison table.
High-speed pulse input/output module
Input
The following functions occupy inputs of the high-speed input/output function. The channels and the axis numbers are in
module internal order.
*1 The number in is the head input number for each high-speed pulse input/output module.
*2 Simultaneous use with a function other than the high-speed counter (A phase/B phase input) is possible. However, using with the
channel 2 external enable input of the high-speed counter is not possible. However, the input logic of other functions is applied.
Output
The following functions occupy outputs of the high-speed input/output function. The channels and the axis numbers are in
module internal order. The following functions cannot be combined with other high-speed input/output functions.
*1 The number in is the head output number for each high-speed pulse input/output module.
Precautions
Do not specify an output device (Y) used by the high-speed input/output function as the output destination of the high-speed
comparison table.
Function Up to CH/axis Device
FX5S/FX5U/FX5UC FX5UJ FX5S/FX5U/FX5UC FX5UJ
PWM
*1
4 CH Y0 to Y7
Positioning PULSE 4 axes 3 axes Y0 to Y3 Y0 to Y2
SIGN Y0 to Y17
CW 2 axis Y0, Y1
CCW Y2, Y3
Clear signal 4 axes 3 axes Y0 to Y17
Device
*1
Input interrupt
*2
High-speed counter Pulse width measurement Positioning
X X CH1 Input A phase 
X+1 X+1 CH1 Input B phase/external preset 
X+2 X+2 CH1 Input external preset Axis2 Zero signal
X+3 X+3 CH2 Input A phase CH1 Axis2 Interrupt input signal 1
X+4 X+4 CH2 Input B phase/external preset CH2 Axis1 Interrupt input signal 1
X+5 X+5 CH2 Input external preset Axis1 Zero signal
X+6 X+6 CH1 Input external enable Axis2 External start signal
X+7 X+7 CH2 Input external enable Axis1 External start signal
Device
*1
PWM Positioning
Y Axis1 PULSE/CW
Y+1 CH1 Axis2 PULSE/CW
Y+2 Axis1 Clear signal
Y+3 Axis2 Clear signal
Y+4 Axis1 SIGN/CCW
Y+5 CH2 Axis2 SIGN/CCW
Y+6 
Y+7 