APPX
Appendix 2 Special Register List
763
A
SD10380
to
SD10395
Simple CPU communication status The simple CPU communication status is
stored.
SD10380: Setting No.1 to SD10395: Setting
No.16
0H: Unset
1H: Preparing
3H: Communicating
4H: Communication stop
5H: Retry being executed
6H: Monitoring at error
AH: Communications impossible
R
SD10396
to
SD10411
The simple CPU communication status is
stored.
SD10396: Setting No.17 to SD10411: Setting
No.32
0H: Unset
1H: Preparing
3H: Communicating
4H: Communication stop
5H: Retry being executed
6H: Monitoring at error
AH: Communications impossible
R
SD10412
to
SD10427
Simple CPU communication error code The cause of the error detected in the simple
CPU communication is stored.
SD10412: Setting No.1 to SD10427: Setting
No.16
0: No error (function not used)
Other than 0: Error code
The value is cleared to 0 with a clear request
from the engineering tool.
R
SD10428
to
SD10443
The cause of the error detected in the simple
CPU communication is stored.
SD10428: Setting No.17 to SD10443: Setting
No.32
0: No error (function not used)
Other than 0: Error code
The value is cleared to 0 with a clear request
from the engineering tool.
R
SD10444
to
SD10459
Simple CPU communication execution interval
(current value)
If "Fixed" is set for communication setting, the
current value of the execution interval is stored.
SD10444: Setting No.1 to SD10459: Setting
No.16
0: Unset (function not used), communications
impossible
Other than 0: Execution interval (unit: ms)
R
SD10460
to
SD10475
If "Fixed" is set for communication setting, the
current value of the execution interval is stored.
SD10460: Setting No.17 to SD10475: Setting
No.32
0: Unset (function not used), communications
impossible
Other than 0: Execution interval (unit: ms)
R
SD10476
to
SD10491
Error response code The error response code detected by simple
CPU communication is stored.
SD10476: Setting No.1 to SD10491: Setting
No.16
R
SD10492
to
SD10507
The error response code detected by simple
CPU communication is stored.
SD10492: Setting No.17 to SD10507: Setting
No.32
R
No. Name Description Compatible CPU module R/W
FX5S FX5UJ FX5U/
FX5UC