764
APPX
Appendix 2 Special Register List
SD10680 Open completion signal b0: Connection No.1
b1: Connection No.2
b2: Connection No.3
b3: Connection No.4
b4: Connection No.5
b5: Connection No.6
b6: Connection No.7
b7: Connection No.8
0: Close/Open not completed
1: Open completed
R
SD10681 Open request signal b0: Connection No.1
b1: Connection No.2
b2: Connection No.3
b3: Connection No.4
b4: Connection No.5
b5: Connection No.6
b6: Connection No.7
b7: Connection No.8
0: No open request
1: Open request exists
R
SD10682 Socket communications receive status signal b0: Connection No.1
b1: Connection No.2
b2: Connection No.3
b3: Connection No.4
b4: Connection No.5
b5: Connection No.6
b6: Connection No.7
b7: Connection No.8
0: No data received
1: Data receiving completed
R
SD10683 Initial status b0: Initial normal completion status
b1: Initialization abnormal completion
0: Not completed
1: Completed
R
SD10692 Predefined protocol ready 0: Not ready
1: Ready
R
SD10710 Predefined protocol setting data error
information protocol number
When a protocol setting data error is detected,
stores the protocol number where the error was
detected.
R
SD10711 Predefined protocol setting data error
information setting type
0 is stored if an error is detected in the packet
setting or element setting.
1 is stored if an error is detected in the protocol
detailed setting.
R
SD10712 Predefined protocol setting data error
information packet number
When an error is detected in the protocol setting
data, stores the packet number that detected the
error.
R
SD10713 Predefined protocol setting data error
information Element number
When an error is detected in the protocol setting
data, stores the element number where the error
was detected.
R
SD10714 Number of registered predefined protocols Stores the protocol number of the registered
protocol setting data.
R
SD10722 Predefined protocol registration (1 to 16) Whether protocol setting data is registered or
not is stored.
R
SD10723 Predefined protocol registration (17 to 32)
SD10724 Predefined protocol registration (33 to 48)
SD10725 Predefined protocol registration (49 to 64)
SD10740 Connection No.1 protocol execution status Stores the status of the protocol being executed
at connection No.1.
0: Unexecuted
1: Waiting for transmission
2: Sending
3: Waiting for data reception
4: Receiving
5: Execution completed
R
No. Name Description Compatible CPU module R/W
FX5S FX5UJ FX5U/
FX5UC