APPX
Appendix 11 Added and Enhanced Functions
943
A
FX5U/FX5UC CPU module
The high-speed pulse I/O module is
supported.
"1.030" or later "1.085P" or later Page 341
Scan time clear function "1.030" or later "1.085P" or later Page 688
Number of conversion digits selection
by SM705 is supported.
"1.040" or later "1.090U" or later Page 689
SFC function is supported. "1.050" or later "1.095Z" or later MELSEC iQ-F FX5 Programming
Manual (Program Design)
Input interrupt delay function "1.050" or later "1.095Z" or later Page 117
Add/Change Function Supported CPU module
firmware version
Supported engineering tool
software version
Reference
The number of settable high-speed
comparison tables was changed from
maximum 4 to 32.
"1.015" or later
*1
"1.015R" or later Page 257
The number of high-speed
comparisons was changed from 4 to
32.
"1.015" or later
*1
"1.015R" or later Page 289
The following modules are supported.
FX5-16ET/ES-H
FX5-16ET/ESS-H
"1.030" or later "1.025B" or later Page 233
Interrupt input signal 1 high-speed
mode is added
"1.030" or later "1.025B" or later Page 395
All module reset when a stop error
occurs is added
"1.030" or later "1.025B" or later Page 397
Positioning table data retaining
function is added
"1.030" or later "1.025B" or later Page 513
Firmware update function From the first version
*2
*3
Page 92
Data logging function "1.040" or later
*4
"1.64S" or later
*5
Page 149
Event history function "1.040" or later
*6
"1.030G" or later Page 138
Internal buffer capacity setting "1.040" or later
*4
"1.030G" or later Page 205
PID control operation setting (ACT)
Overshoot suppression setting
Hunting suppression setting
"1.040" or later "1.030G" or later Page 602
The following modules are supported.
FX5-4AD-PT-ADP
FX5-4AD-TC-ADP
"1.040" or later "1.030G" or later MELSEC iQ-F FX5 User's Manual
(Analog Control - CPU module built-
in, Expansion adapter)
File transfer function (FTP server) "1.040" or later
*4*7
"1.030G" or later MELSEC iQ-F FX5 User's Manual
(Communication)
iQ Sensor Solution
Automatic detection of connected
devices
Communication setting reflection of
Ethernet device
Sensor parameter read/write
"1.040" or later "1.030G" or later iQ Sensor Solution Reference
Manual
CC-Link IE Field Network Basic
function
"1.040" or later "1.030G" or later CC-Link IE Field Network Basic
Reference Manual
Data backup/restoration function "1.045" or later
*8
Page 207
Memory dump function "1.050" or later
*4
"1.035M" or later Page 196
IP filter function "1.050" or later "1.035M" or later MELSEC iQ-F FX5 User's Manual
(Communication)
Parallel link function "1.050" or later "1.035M" or later MELSEC iQ-F FX5 User's Manual
(Communication)
The following module is supported.
FX5-CCL-MS
"1.050" or later "1.035M" or later MELSEC iQ-F FX5 User's Manual
(CC-Link)
The following module is supported.
FX5-20PG-P
"1.050" or later "1.035M" or later Page 341
Add/Change Function Supported CPU module
firmware version
Supported engineering tool
software version
Reference