Appendix 11 Added and Enhanced Functions
The following modules are supported.
• FX5-8AD
"1.050" or later "1.035M" or later MELSEC iQ-F FX5 User's Manual
(Analog Control - Intelligent function
module)
The following modules are supported.
• FX5-4LC
"1.050" or later "1.035M" or later MELSEC iQ-F FX5 User's Manual
(Temperature Control)
The following module is supported.
• FX5-ASL-M
"1.050" or later "1.035M" or later MELSEC iQ-F FX5 User's Manual
(AnywireASLINK)
Real-time monitor function "1.060" or later
*9
Page 227
Support extended file register
function
"1.060" or later
*4
"1.040S" or later Page 68
MODBUS/TCP communication
function
"1.060" or later "1.040S" or later MELSEC iQ-F FX5 User's Manual
(Communication)
Time setting function (SNTP client) "1.060" or later "1.040S" or later MELSEC iQ-F FX5 User's Manual
(Communication)
Web server function "1.060" or later "1.040S" or later MELSEC iQ-F FX5 User's Manual
(Communication)
MELSEC iQ-R/MELSEC iQ-F Web
Server Function Guide Book
Support S(P).DEVLD, SP.DEVST,
ERREAD, ERWRITE, ERINIT and
RTM instruction
"1.060" or later
*10
"1.040S" or later MELSEC iQ-F FX5 Programming
Manual (Instructions, Standard
Functions/Function Blocks)
Support "Use MC/MCR for control of
EN" of the subroutine type FB
"1.060" or later "1.040S" or later GX Works3 Operating Manual
The following modules are supported.
• FX5-4AD
•FX5-4DA
"1.050" or later "1.040S" or later MELSEC iQ-F FX5 User's Manual
(Analog Control - Intelligent function
module)
During IP address duplication with
the device on the same network, the
operation was improved to output the
information of the external device
with duplicated IP address.
"1.061" or later MELSEC iQ-F FX5 User's Manual
(Communication)
Keep of latch label during PC write by
SM9353
"1.065" or later Page 133
Expanding the number of input/output
points to 384 points.
"1.100" or later "1.047Z" or later MELSEC iQ-F FX5S/FX5UJ/FX5U/
FX5UC User's Manual (Hardware)
Removing the limitation on the
number of remote I/O points. (384
points)
(However, the total number of remote
I/O points and input/output points is
512 points or less.)
"1.100" or later "1.047Z" or later MELSEC iQ-F FX5S/FX5UJ/FX5U/
FX5UC User's Manual (Hardware)
Expanding the program capacity up
to 128000 steps.
"1.100" or later "1.047Z" or later MELSEC iQ-F FX5S/FX5UJ/FX5U/
FX5UC User's Manual (Hardware)
Divided writing of the program and
program restoration information of
online change
"1.100" or later "1.047Z" or later Page 113
User Web page is supported. "1.100" or later "1.047Z" or later MELSEC iQ-F FX5 User's Manual
(Communication)
MELSEC iQ-R/MELSEC iQ-F Web
Server Function Guide Book
The following module is supported.
• FX5-20PG-D
"1.050" or later "1.050C" or later MELSEC iQ-F FX5 User's Manual
(Positioning Control - Intelligent
function module)
The following module is supported.
•FX5-ENET
"1.110" or later "1.050C" or later MELSEC iQ-F FX5-ENET User's
Manual
The following module is supported.
•FX5-DP-M
"1.110" or later "1.050C" or later MELSEC iQ-F FX5 User's Manual
(PROFIBUS)
Expanding the number of remote I/O
station of CC-Link IE field network
Basic from 6 to 16 stations.
"1.110" or later "1.050C" or later MELSEC iQ-F FX5S/FX5UJ/FX5U/
FX5UC User's Manual (Hardware)
Add/Change Function Supported CPU module
firmware version
Supported engineering tool
software version