M Series AC Servo
User Manual
152
Rev. 1.0
7/31/2019
400-820-9661
40153 R/W SHORT Electronic Ration Denominator(ED)
40154 Read Only SHORT Step Mode (SZ)
40155 R/W SHORT Position Fault(PF)
40156 R/W SHORT Dynamic Position Error Count(PL)
40157 R/W SHORT In-Position Counts(PD)
40158 R/W SHORT In-Position Timing(PE)
40159 R/W SHORT Pulse Complete Timing(TT)
40160 R/W SHORT Analog Velocity Gain(AG)
40161 R/W SHORT Analog Torque Gain(AN)
40162 R/W SHORT Analog Offset 1(AV1)
40163 R/W SHORT Analog Offset 2(AV2)
40164 R/W SHORT Analog Type(AS)
40165 R/W SHORT Analog Deadband 1(AD1)
40166 R/W SHORT Analog Deadband 2(AD2)
40167 R/W SHORT Analog Deadband (AD)
40168 R/W SHORT Analog Function(FA)
40169 R/W SHORT Servo Enable(SI)
40170 R/W SHORT Alarm Reset(AI)
40171 R/W SHORT Define Limits Input(DL)
40172 R/W SHORT Motion Input
40173 R/W SHORT Alarm Output(AO)
40174 R/W SHORT Brake Output(BO)
40175 R/W SHORT Motion Output(MO)
40176 R/W SHORT Reserved
40177 R/W SHORT Communication Protocol(PR)
40178 R/W SHORT Transmit Delay(TD)
40179 R/W SHORT Baud Rate(BR)
40180 R/W SHORT Communication Address(DA)
40181 R/W SHORT Velocity value(VR)
40182 R/W SHORT Tach-out Count(TO)