EasyManua.ls Logo

Motorola WiNG 5.5 - Page 420

Motorola WiNG 5.5
954 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 - 334 WiNG 5.5 Access Point System Reference Guide
Figure 5-215 Device Overrides - Advanced Profile MINT screen - IP (Add)
25. Set the following Link IP parameters to complete the MINT network address configuration:
IP Define or override the IP address used by peer access points for interoperation when
supporting the MINT protocol.
Routing Level Use the spinner control to define or override a routing level of either 1 or 2.
Listening Link Specify a listening link of either 0 or 1. UDP/IP links can be created by configuring a
matching pair of links, one on each end point. However, that is error prone and doesn’t
scale. So UDP/IP links can also listen (in the TCP sense), and dynamically create
connected UDP/IP links when contacted.
Port To specify a custom port for MiNT links, select this option and use the spinner control
to define or override the port number from 1 - 65,535.
Forced Link Select this option to specify the MiNT link as a forced link. This setting is disabled by
default.
Link Cost Use the spinner control to define or override a link cost from 1 - 10,000. The default
value is 100.
Hello Packet Interval Set or override an interval in either Seconds (1 - 120) or Minutes (1 - 2) for the
transmission of hello packets. The default interval is 15 seconds.