3-74
Memory Switch 61 – Remote reception
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Factory use only
6 0 Factory use only
5 1 Factory use only
4 1 Factory use only
3 0
2 1
1 0
0 0
Off-hook / on-hook detect
time
Sets the time interval between the on-hook and off-
hook (or off-hook/on-hook) condition.
Switch 3 2 1 0 Time
0 0 0 0 0 ms
0 0 0 1 100 ms
0 0 1 0 200 ms
0 0 1 1 300 ms
0 1 0 0 400 ms Initial setting
0 1 0 1 500 ms
0 1 1 0 600 ms
0 1 1 1 700 ms
1 0 0 0 800 ms
1 0 0 1 900 ms
1 0 1 0 1000 ms
1 0 1 1 1100 ms
1 1 0 0 1200 ms
1 1 0 1 1300 ms
1 1 1 0 1400 ms
1 1 1 1 1500 ms