3-79
Memory Switch 70 – Operation
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Display error line
0: No
1: Yes
The number of error lines contained in the received
data will be shown in the LCD.
6 0 Tonal line monitor
0: No
1: Yes
Allows fax communication to be heard through the
monitor speaker.
5 0 Factory use only
4 0 Sort autodialer printout
0: Sort by autodialer location
1: Sort by location ID
Specifies how entries on autodialer printouts are
sorted.
3 1 Print check message if power
is lost
0: No
1: Yes
In the event of two power losses in a 40–hour
period, documents will be lost. When power is
restored, a check message will print.
2 1 Print page if error occurs
during memory transmission
0: No
1: Yes
For easy identification, the first page of a document
stored for memory transmission will print along a
check message if an error occurs during memory
transmission.
1 1 Print check message
0: No
1: Yes
To notify the user of an error, a check message can
be printed if a communication error occurs.
0 0 Factory use only