3-61
Memory Switch 00 – Dialer
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Factory use only
6 0 Factory use only
5 0
4 0
CED detection condition Sets whether the detection should be strict or not.
Normal Å ÆStrict
350ms 500ms 700ms 1000ms
Switch 5 0 0 1 1
4 0 1 0 1
3 0 DIS detect time after dialing
0: 55 sec
1: 70 sec
Sets the time DIS signal is detected after dialing a
number.
2 1 CED detection
0: No
1: Yes
Can be use to ignore CED detection if noise on the
telephone line is mistaken as a 2100 Hz CED
signal.
1 1 Dial tone detection
0: Do not dial
1: Dial
Determines if the machine proceeds with dialing or
indicates an error if no dial tone is detected within
five seconds of going off–hook.
0 0 Phone line type for the first
phone line
0: PSTN
1: PBX
When set to PSTN, the machine checks for dial
tone and acts according to the setting of memory
switch 00, bit 1. When set to PBX, the machine
always dials a given number of seconds after going
off–hook. Memory switch 001 sets the number of
seconds.

Table of Contents

Other manuals for Muratec F-315

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Muratec F-315 and is the answer not in the manual?

Muratec F-315 Specifications

General IconGeneral
BrandMuratec
ModelF-315
CategoryAll in One Printer
LanguageEnglish

Related product manuals