Page #88 background imageLoading...
Page #88 background image
3-62
Memory Switch 01 – Dialer
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Factory use only
6 0 Factory use only
5 0
4 0
DIS detection condition Sets whether the detection should be strict or not.
Normal Å ÆStrict
200ms 300ms 400ms 500ms
Switch 5 0 0 1 1
4 0 1 0 1
3 0
2 0
1 1
0 1
PBX mode dial pause Sets the number of seconds the machine waits
before dialing when memory switch 002, bit 0 is set
to PBX mode.
Switch 3 2 1 0 Pause time
0 0 0 0 0 sec
0 0 0 1 1 sec
0 0 1 0 2 sec
0 0 1 1 3 sec Initial setting
0 1 0 0 4 sec
0 1 0 1 5 sec
0 1 1 0 6 sec
0 1 1 1 7 sec
1 0 0 0 8 sec
1 0 0 1 9 sec
1 0 1 0 10 sec
1 0 1 1 11 sec
1 1 0 0 12 sec
1 1 0 1 13 sec
1 1 1 0 14 sec
1 1 1 1 15 sec