3-63
Memory Switch 02 – Dialer
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Factory use only
6 0 Factory use only
5 0 Factory use only
4 0 Factory use only
3 0 Factory use only
2 0 Factory use only
1 0 Factory use only
0 0
(EUR)
1 (US)
Redial when D.0.7 error
occurred
0 : Yes
1 : No
[This Switch is for US only]
When this switch is set to “1”, the machine does not
auto-redial to the remote machine when the remote
unit did not answer the call within the incoming
detection time (D.0.7 error).
Memory Switch 03 – Factory use only
Memory Switch 04 – Dialer
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Factory use only
6 0 Factory use only
5 0 Factory use only
4 0 Factory use only
3 1 See table below
2 0 Note: The setting of this switch is available only
1 0 when setting other than 0.
0 0
DTMF attenuation
Memory Switch 04…DTMF attenuation
Switch –15
dB
–14
dB
–13
dB
–12
dB
–11
dB
–10
dB
–9
dB
–8
dB
–7
dB
–6
dB
–5
dB
–4
dB
–3
dB
–2
dB
–1
dB
–0
dB
3 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
2 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0
1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0

Table of Contents

Other manuals for Muratec F-315

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Muratec F-315 and is the answer not in the manual?

Muratec F-315 Specifications

General IconGeneral
BrandMuratec
ModelF-315
CategoryAll in One Printer
LanguageEnglish

Related product manuals