EFA-200/-300 11 Remote control
11-11
Harmonic Analysis mode
The “Run” state should be activated.
Start measurement
C190
Stop measurement
C192
Read measurement status
C 195 0 = Stop
1 = Run
Write/action
commands
Read commands Range of p Meaning or
Unit of p
Select/read fundamental FUND (for definition see fundamental frequencies)
C164 <p> C165 1...6 Running index
within available
list
Select/read detection mode
C162 <p> C163 0 = ACT RMS
1 = AVG RMS
2 = VECT PEAK
Select/read averaging parameter
C120 <p> C121 0 = 4
1 = 8
2 = 16
3 = 32
NAVG
Table 11-5 Remote control commands, Harmonic Analysis mode
Write/action
commands
Read commands Range of p Meaning or
Unit of p
Table 11-4 Remote control commands, Spectrum FFT mode