Electra Elite IPK II Document Revision 4C
Transfer 2 - 985
 20-11-18 Class of Service Options (Hold/Transfer Service) – No Recall
Allow (0)/Deny (1) unanswered Transferred calls to the COS from recalling the originating
extension.
(default: 0)
 For example, with this option set to 1 for COS 1, calls transferred by any COS to any extension with
a COS of 1, do not recall.
 20-11-20 Class of Service Options (Hold/Transfer Service) – No Callback
Allow (0)/Deny (1) unanswered Transferred calls from the COS from recalling the originating
extension.
(default: 0)
 For example, with this option set to 1 for COS 1, any call transferred by an extension with COS 1,
does not recall.
 20-13-10 Class of Service Options (Supplementary Service) – Barge-In Monitor
Enable the Barge-In Speech Mode (0) at the initiating extension (i.e., Barge-In initiator). This is
required to transfer a call to a conference.
(default: 0)
 20-13-15 Class of Service Options (Supplementary Service) – Barge-In, Initiate
Enable (1)/Disable (0) the ability to Barge-In to a call.
(default: 0)
 20-13-16 Class of Service Options (Supplementary Service) – Barge-In, Receive
Enable (1)/Disable (0) the ability to receive a Barge-In on a call.
(default: 0)
 20-13-17 Class of Service Options (Supplementary Service) – Barge-In Tone/Display (Intrusion
Tone)
Enable (1)/Disable (0) the Barge-In Tone. If disabled, this also turns off the Barge-In display at
the called extension. As this option is for extensions and trunks do not have an option for a
Barge-In Tone, the tone is sent to the trunks based on the Class of Service of the transferring
extension.
(default: 1)
 20-13-32 Class of Service Options (Supplementary Service) – Deny Multiple Barge-Ins
Enable (1)/Disable (0) an extension user ability to have multiple users Barge-In to their
conversation.
(default: 0)
 20-14-11 Class of Service Options For DISA/E&M – DISA/Tie Trunk Barge-In
Determine if DISA and tie trunk users should dial a service code to Barge-In to a conference call.
0 = Disabled
1 = Enabled
(default: 0)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Electra Elite IPK II System and is the answer not in the manual?

NEC Electra Elite IPK II System Specifications

General IconGeneral
BrandNEC
ModelElectra Elite IPK II System
CategoryTelephone System
LanguageEnglish

Related product manuals