Description
The Flexible Timeouts feature provides a variety of timers in the Resident System Program to allow the
system to operate without initial programming. The system timers can be changed to meet customer
needs according to the system application requirements.
A Timer Class allows terminals and trunks to have different timers for the same feature. There are 16
timer Classes (0~15). The following table shows the Programs that are used depending on the Timer
Class used:
Timer
Class 0
Timer
Class 1~15
Title Comment
20-01-08 20-31-01 Trunk Queuing Callback
Time
Trunk Queuing callback rings an extension for this
time. Station Timer Class is referred by the station
that sets trunk queuing.
20-01-09 20-31-02 Callback / Trunk Queuing
Cancel Time
The system cancels an extension Callback or
Trunk Queuing request after this time. Station
Timer Class is referred by the station that sets an
extension Callback or Trunk Queuing.
20-04-03 20-31-03 CAR/SIE/Virtual Extension
Delay Interval
If CAR/VE is set for Delayed Ringing (Program
15-11-01), ring the covering extension after this
time. Station Timer Class is referred by the station
assigned to CAR/VE.
21-01-02 20-31-04 Intercom Interdigits Time When placing Intercom calls, users must dial each
digit during this time. Station Timer Class is
referred by stations. Trunk Timer Class is referred
by DID/Automatic Answer Trunk/E&M trunks.
21-01-03 20-31-05 Trunk Interdigits Time When placing CO calls, users must dial each digit
during this time. Station Timer Class is referred by
stations. Trunk Timer Class is referred by DID/
Automatic Answer Trunk/E&M trunks.
21-01-09 20-31-06 Hotline Time Start Time A Ringdown extension automatically calls its
programmed destination after this time. Station
Timer Class is referred by the station which sets
Hotline.
22-01-03 20-31-07 Ring No Answer Alarm
Time
If a trunk rings a key telephone longer than this
time, the system changes the ring cadence. This
indicates to the user that the call has been ringing
too long. Trunk Timer Class is referred by the
trunk.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Electra Elite IPK II System and is the answer not in the manual?

NEC Electra Elite IPK II System Specifications

General IconGeneral
BrandNEC
ModelElectra Elite IPK II System
CategoryTelephone System
LanguageEnglish

Related product manuals