Electra Elite IPK II Document Revision 4C
Automatic Route Selection 2 - 85
The examples below use the following system programming:
Program 26-02 for Dial Analysis Table for ARS set as:
Table No.
Program 26-02-01
Dial
Program 26-02-02
Service Type
Program 26-02-03
Add Data
Program 26-02-04
ARS COS
1 203@@@@@@@ 1:Route to trunk group 3 (Group 3) 5
2 214@@@@@@@ 1:Route to trunk group 1 (Group 1) 4
197 @@@@@@@@@@ 1:Route to trunk group 2 (Group 2) 4
198 @@@@@@@@@@ 1:Route to trunk group 3 (Group 3) 3
199 @@@@@@@@@@ 1:Route to trunk group 2 (Group 2) 2
200 @@@@@@@@@@ 1:Route to trunk group 1 (Group 1) 1
Program 12-02 for Automatic Night Service Patterns as:
Time
Pattern No.
Program 12-02-01
Start Time
Program 12-02-02
End Time
Program 12-02-03
Operation Mode
1 00:00 08:30 2 (Night)
2 08:30 17:00 1 (Day)
3 17:00 00:00 2 (Night)
Program 12-02 for Automatic Night Service Patterns as:
Mode Ext. 301 Ext. 302 Ext. 401 Ext. 402
Mode 1 (Day)1233
Mode 2 (Night)1435