EasyManuals Logo

NEC Electra Elite IPK II System User Manual

NEC Electra Elite IPK II System
1190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #123 background imageLoading...
Page #123 background image
Electra Elite IPK II Document Revision 4C
Barge-In 2 - 99
 11-16-02 One-Digit Service Code Setup – Barge-In
Set up Item 02 for single digit Barge-In. For example, you can assign Item 02 to use digit 5 for
Barge-In. This allows you to program a function key with an extension number plus the Barge-In
code (i.e., 5). This allows one-touch access to Barge-In for an extension.
 15-07-01 Programmable Function Keys
Assign a function key for Barge-In (code 34).
 20-06-01 Class of Service for Extensions
Assign a Class of Service (1~15) to an extension.
 20-13-10 Class of Service Options (Supplementary Service) – Barge-In Monitor
For extension Class of Service, enable the Barge-In Speech Mode (0) or Monitor Mode (1) at the
initiating extension (i.e., Barge-In initiator).
 20-13-15 Class of Service Options (Supplementary Service) – Barge-In, Initiate
Enable (1)/Disable (0) Barge-In at the initiating extension (i.e., Barge-In initiator).
 20-13-16 Class of Service Options (Supplementary Service) – Barge-In, Receive
Enable (1)/Disable (0) Barge-In at the receiving extension (i.e., Barge-In receive).
 20-13-17 Class of Service Options (Supplementary Service) – Barge-In Tone/Display (Intrusion
Tone)
Enable (1)/Disable (0) the Barge-In (Intrusion) Tone. If disabled, this also turns off the Barge-In
display at the called extension.
 20-13-32 Class of Service Options (Supplementary Service) – Multiple Barge-Ins
Enable (1)/Disable (0 the extension user ability to have multiple users Barge-In to their
conversation.
 20-14-11 Class of Service Options for DISA/E&M – DISA/Tie Trunk Barge-In
Enable (1)/Disable (0 a DISA or tie trunk user from using the Barge-In feature with the service
code defined in Program 11-12-08.
 20-18-07 Service Tone Timers – Intrusion Tone Repeat Time
After a user barges in, the system repeats the Barge-In tone after this time.
 21-01-03 System Options for Outgoing Calls – Trunk Interdigit Time (External)
Program the time an extension must wait before the Barge-In feature can be used on a call (this
time must expire before a call is put in a talk state). This time also affects Voice Over.
Operation
To Barge-In after calling a busy extension:

The time in PRG 21-01-03 must expire before you can Barge-In.
1. Call a busy extension.
2. Press Barge-In key (PRG 15-07-01 or SC 751: 34).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Electra Elite IPK II System and is the answer not in the manual?

NEC Electra Elite IPK II System Specifications

General IconGeneral
BrandNEC
ModelElectra Elite IPK II System
CategoryTelephone System
LanguageEnglish

Related product manuals