2 - 204 Class of Service
Default Setting
The attendant (extension 101) has Class of Service 15 in all Night Service modes. All other
extensions have Class of Service 1 in all Night Service modes.
Refer to Table 2-6 through Table 2-13 in this section for the default settings of the individual
options.
If changing Class of Service via Service Code:
An extension can use Service Code 677 to change another extension Class of Service
(Program 20-13-28 = 1).
An extension can automatically block another extension attempt to change their Class of
Service via Service Code 677 (Program 20-13-28 = 0).
The default Service Code for this option is 677 (Program 11-11-24 = 677).
System Availability
Terminals
All Stations
Required Component(s)
None
Related Features
Night Service
Programming
11-11-24 Service Code Setup (for Setup/Entry Operation) – Change Station Class of Service
If required, change the Service Code a user dials to change an extension Class of Service.
20-06-01 Class of Service for Extensions
Assign a Class of Service to extensions (1~15). Any Class of Service assignment you change
using Service Code 677 (see below) automatically updates this program.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Electra Elite IPK II System and is the answer not in the manual?

NEC Electra Elite IPK II System Specifications

General IconGeneral
BrandNEC
ModelElectra Elite IPK II System
CategoryTelephone System
LanguageEnglish

Related product manuals