Electra Elite IPK II Document Revision 4C
Direct Inward Line (DIL) 2 - 339
Group Call Pickup
Name Storing
Off-Hook Signaling
Paging, External
Programmable Function Keys
Ring Groups
Transfer
Programming
15-07-01 Programmable Function Keys
To have the DIL ring a key, program a line key for the DIL trunk.
20-06-01 Class of Service for Extensions
Assign a Class of Service (1~15) to an extension.
20-09-01 Class of Service Options (Incoming Call Service) – Second Call for DID/DISA/DIL/E&M
Override
Enable (1)/Disable (0) the ability to receive a second call from a DID, DISA, DIL, or Tie Line
caller.
20-13-23 Class of Service Options (Supplementary Service) – Display the Reason for Transfer
Enable (1)/Disable (0) the display of the reason (Call Forward, Busy, No Answer or DND) a
VRS, DID, DISA, or ISDN call is being transferred.
22-01-04 System Options for Incoming Calls – DIL No Answer Recall Time
Set the DIL No Answer Time (0~64800 seconds). If DIL Delayed Ringing is set in Program
22-08, this option sets the DIL Delayed Ring time.
22-02-01 Incoming Call Trunk Setup
Assign each DIL Service Type 4. Make an entry for each Night Service mode.
22-04-01 Incoming Extension Ring Group Assignment
Assign the extensions that should receive the overflow to the ring group programmed in PRG
22-08. Set the ringing in Program 22-06.
0 = Trunks Do Not Ring, but flash line keys.
1 = Trunks Ring