Document Revision 4C Electra Elite IPK II
2 - 386 Drop Key
Programming
11-12-42 Service Code Setup (for Service Access) – Flash on Trunk lines
Default is #3.
11-12-59 Service Code Setup (for Service Access) – Trunk Drop Operation for SLT
Default is Not Assigned.
14-02-03 Analog Trunk Data Setup – Flash Type
Select the flash type.
0 = Open Loop Flash
1 = Ground
Always set this option to 0.
14-02-04 Analog Trunk Data Setup – Hooking Type
For each trunk, indicate if Flash is for one of the following:
0 = Timed Flash
1 = Disconnect
15-02-05 Multiline Telephone Basic Data Setup – Transfer Key Operation Mode
If the Conf key should access Flash, enter 2. Otherwise, enter 0 or 1.
15-03-04 Single Line Telephone Basic Data Setup – Flashing
In a single line (500/2500 type) telephone Class of Service, Enable (1)/Disable (0) an extension
user ability to hookflash for system feature access.
15-07-01 Programmable Function Keys
Assign a function key for Drop Key (code 84) if required.
20-06-01 Class of Service for Extensions
Assign a Class of Service (1~15) to an extension.
81-10-07 COI Initial Data Setup – Hookflash Time Selection 1
Set the Flash duration (20 ms~5.0 sec) for analog trunk [COI( )-U( ) ETU] circuits.
81-10-08 COI Initial Data Setup – Hookflash Time Selection 2
Set the open loop disconnect duration (20 ms~5.0 sec) for analog trunk [COI( )-U( ) ETU]
circuits.
Operation
To use the Drop key from a Multiline Terminal with a CO/PBX call in progress: