Electra Elite IPK II Document Revision 4C
E911 Compatibility 2 - 413
Conditions
If Program 21-01-10 is set to an entry other than 0, a call does not have a talk path unless
the user dials at least the number of digits entered in this option when placing an outgoing
call. An entry of 4 digits or higher causes a problem when dialing 911. Since it is only a
3-digit number, the call does not have a talk path, preventing the emergency dispatcher
from hearing the caller. This option should be kept at its default setting of 0 to prevent any
problem with dialing 911.
CAMA Trunks are not supported.
If a 911 call originates from a Virtual Extension, the system sends the Virtual Calling Party
Number (CPN) Presentation from Station.
Default Setting
Disabled
Programming
11-12-56 Service Code Setup (for Service Access) – E911 Alarm Shut Off
Select the Service Code (normally 786) an extension user dials to shut off the E911 Alarm Ring.
14-05-01 Trunk Group – Trunk Group Number
Assign the outbound trunks you want to use for E911 service to the same Trunk Group.
Trunk Groups: 1~100
14-06-01 Trunk Group Routing
Set up an outbound routing table for trunk groups assigned in Program 14-05. This program and
Program 21-02 are the minimum required if E911 must seize a line to dial.
Trunk Group Routes: 1~100
20-06-01 Class of Service for Extensions
Assign a Class of Service to an extension (1~15).
20-08-16 Class of Service Options (Outgoing Call Service – Display E911 Dialed Extension Name
and Number
Enable (1)/Disable (0) the ability to display the name and number of the extension that activated
E911 service. If disabled (0), the E911 Alarm (set in Program 21-01-13) never occurs.
21-01-12 System Options for Outgoing Calls – Dial E911 Routing Without Trunk Access
If enabled (1), an extension user can dial 911 without first dialing a trunk access code or
pressing a line key. If disabled (0), an extension user must dial a trunk access code (e.g., 9) or
press a line key before dialing 911. If enabled, dialing 9+911 still dials out.
21-01-13 : System Options for Outgoing Calls – Alarm Ring Timer (E911)
Set the duration of the E911 Alarm Ring Time (0~64800 seconds). If set to 0 (default), the E911
Alarm does not ring.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Electra Elite IPK II System and is the answer not in the manual?

NEC Electra Elite IPK II System Specifications

General IconGeneral
System TypeHybrid
VoIP SupportYes
ISDN SupportYes
T1/E1 SupportYes
Caller IDYes
VoicemailYes
Auto AttendantYes
Music on HoldYes
Conference CallingYes
Call ForwardingYes
Call TransferYes
Call WaitingYes
Power Requirements100-240 VAC, 50/60 Hz
TypeTelephone System
Analog PortsYes
Digital PortsYes
CompatibilityNEC Digital and IP Phones, Analog Phones
DimensionsVaries depending on chassis and expansion cards
WeightVaries depending on chassis and expansion cards