Document Revision 4C Electra Elite IPK II
2 - 544 IP Station (MEGACO) – MG 16
Related Features
None
Programming
10-16-03 Option Information Setup – TFTP Server (Version 1600 and 2100 or higher required)
IP Address
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
(default: 0.0.0.0)
VoIP Settings:
When the PVA(X)-U( ) ETU is first purchased it has a factory default package installed. You have to
load the MG16 Application for the Elite IPK II KSU to recognize the VoIP MG16 ETU. [Refer to the
PVA(X)-U( ) ETUs Firmware upgrade installation procedure].
84-05-01 VoIP IP Address – IP Address
Define the IP Address of the VoIP Application supported (MG16, CCISoIP). (default: Slot 1:
172.16.0.20)
84-05-02 VoIP IP Address – LAN Interface
Define the LAN interface Speed and Mode of the VoIP Application supported (MG16, CCISoIP).
(default: 0 = AUTO)
84-05-03 VoIP IP Address – Master/Slave
Define the Media Gateway Controller for the MG16 application.
(default: 1 = MASTER)
The Elite IPK II system supports only one Media Gateway controller (determined by setting the MG16
Application to Master).
84-05-04 VoIP IP Address – Subnet Mask
Define the Media Gateway Card Subnet Mask Address.
(default: 255.255.0.0)
84-05-05 VoIP IP Address – Default Gateway
Define the MG16 Application Default Gateway Address.
(default: 0.0.0.0)
84-06-01 VoIP Info – RTP Port Number
Define the Media Gateway Card starting RTP Port Number.
(default: 10020)