Electra Elite IPK II Document Revision 4C
Alarm Reports 2 - 33
Table 2-2 Alarm Report Definitions
Alarm Report Heading Definitions
LVL Alarm Type (MAJ = Major, MIN = Minor)
NO Number of Alarm (4-digit)
STAT Status (REC = Recovered, ERR = Error, WAR = Warning
DATE Date the Alarm Occurred
TIME Time the Alarm Occurred
ITEM Name of the Alarm
UNIT Name of the ETU
SLT KSU Slot Number
PRT KSU Port Number
PARAMETER Related Information
Table 2-3 Alarm Report Item Definitions
Item Name Definition
PKG Installation ETU is removed or inserted.
ISDN Link ISDN Line failure is detected.
CPU – LAN Link CPU – Lan connection failure is detected.
Blocking Terminal Failure may have occurred because terminal
blocking is detected. Terminal is unplugged or wire is
disconnected.
System Data Change System Upgrade performed or Programming change.
System Start Up System is reset.
SMDR Link Connection failure has been detected between the CPU
and SMDR printer device.