10. 84-11-10 G.729 Jitter Buffer Average (default: 60 ms)
11. 84-11-11 G7.29 Jitter Buffer Max (default: 120 ms)
12. 84-11-17 Jitter Buffer Mode – support Static or Immediate (default: 2: Immediate)
13. 84-11-18 Voice Activity Detection Threshold [default: 20 = 0dB (-30dBm)]
14. 84-11-20 Echo Canceller Mode (default: 1: Enable)
15. 84-11-22 Echo Canceller NLP Mode (default: 1: Enable)
16. 84-11-26 TX Gain (default: 14)
17. 84-11-27 RX Gain (default: 14)
84-11-28 : D
term
IP CODEC Information Settings – Audio Priority
For each Type, set the codec to use (default = G.711). By default, all IP Phones belong in Type 1.
To change the Type for an IP Phone:
15-05-15 : IP Phone Terminal Basic Data Setup – CODEC Type
For each IP Phone (extension number), select the Type to use (default:1).
System Tones and Ring Tones:
System IP Phones do not use Program 80-01 : Service Tone Setup entries. The tones are generated
locally by the System IP Phone. When a Door Box chime rings a System IP Phone, the system activates
the chimes using a ring command. Because of this, if the volume is adjusted while the door chime is